Brand Name: | Micommon |
Model Number: | ST-30K |
Certification: | CE |
Place of Origin: | China |
MOQ: | 1 |
Price: | Negotiable |
Payment Terms: | T/T, D/P, D/A, L/C |
Supply Ability: | 2000 Piece/Pieces per Month |
Delivery Time: | 15days |
Packaging Details: | 1 Humidifier, 16-foot tube, 1 Printed Users Manual, 1 Power Cord |
Warranty:: | 2 years |
Instrument classification:: | Class II |
Quality Certification:: | CE |
Safety standard:: | ISO 13485 |
Ventilation mode:: | S/T, CPAP, S, T, PC, VAT, HFNC |
Waveform display:: | Pressure/flow |
IPAP:: | 4~40cm H20 |
Backup BPM:: | 1~60BPM |
Non-invasive Ventilator High Flow Therapy CE Certificated Medical Respiratory with HFNC SOLUTION
HOSPITAL NON-INVASIVE VENTILATOR with HFNC SOLUTION
High Performance Non-invasive Ventilation Solution Perfect Combination of NIV and HFNC
Application
Chronic Obstructive Pulmonary Disease
Acute Exacerbation of Chronic Obstructive Pulmonary Disease
Moderate Acute Respiratory Distress Syndrome
Acute Cardiac Edema
Other ventilation problems
Main features
1. Higher treatment pressure, more leak compensation.
In case of high inhalation pressure support (40cm H20) orlarge air leakage, it can still ensure an accurate and
stablepressure platform.
Inhalation time function: the minimum spontaneousinhalation time
(Timin) prevents premature reversing toexhalation to ensure
ventilation time; the maximum (Timax)spontaneous inhalation time
prevents the difficulty ofexhalation reversing caused by excessive
leakage
2. AST-Premium automatic synchronizationtechnology,excellent
man-machine synchronization.
The VAT can provide tidal volume similar to volume contramode, and
also has the safety of pressure control mode.
3. Accurate oxygen concentration control, more efficient to improve
Pa02.
- The oxygen concentration is accurate and constant.the effect of
improving blood oxygen saturation is better
- Connect directly with central oxygen supply system,function
without extra oxygen flow indicator
- Real-time display of oxygen concentration,abnormal oxygen
concentration alarm for oxygertherapy safety
4. Inhalation time function.
the minimum spontaneousinhalation time (Timin) prevents premature reversing toexhalation to ensure ventilation time; the maximum (Timaspontaneous inhalation time prevents the difficulty ofexhalation reversing caused by excessive leakage.
5. Complete parameters setting.
Trigger-lock function: it can reduce false triggers caused by small
airway spasmand airway jitter during exhalation, and
improveman-machine synchronization.
6. 8 hours back-up battery.
Humidifier parameters
ST-30H | ST-30K | |
Heating range | 40-70. | |
Adjustment | 1-9 level |
Specifications
Parameter | ST-30H | ST-30K |
Ventilation mode | S/T, CPAP, S, T, PC, VAT | S/T, CPAP, S, T,PC, VAT, HFNC |
Oxygen concentration | 21%-100%, (increment by 1%) | |
Screen size | 5.7 inch color screen | |
Waveform display | Pressure/flow | |
IPAP | 4-30cm H2O | 4-40cm H2O |
EPAR | 4-25cm H2O | |
CPAP | 4-20cm H2O | |
Target tidal volume | 20-2500mL | |
Backup BPM | 1-60BPM | |
Backup time | 0.2 -4.0 S | |
Rise time | 1-6 level | |
Ramp time | 0-60min (increment by 1 min) | |
Ramp pressure | CPAP mode: 4-20cm H20 Other mode: 4-25cm H20 | |
Pressure relief | 1-3 level | |
Spontaneous Timin | 0.2-4.0 S | |
Spontaneous Timax | 0.2-4.0 S | |
I-Trigger setting | Auto, 1-3 level | |
E-Trigger setting | Auto, 1-3 level | |
Trigger lock | Off, 0.3-1.5S | |
Flow of HFNC mode | N/A | 10-70L/min |
Max flov | 210L/min | 300L/min |
Max leak compensation | 90L/min | 120L/min |
Method of pressure measure | The pressure testing tube is on mask side | |
Alarms | Apnea | Disconnection | Low minute volumel Low tidal volume | Power off | Over high pressure | Oxygen unavailable | Excessive oxygen pressure supply | Low oxygen pressure supply | Pressure tube off | Turbine dysfunction|Oxygen sensor failure | Air flow sensor failure | Low pressure | Low battery | Battery depleted | |
Apnea alarm range setting | 0s, 10S, 20S, 30S | |
Disconnection alarm range setting | 0S, 15S, 60S | |
Real-time monitoring data | Preset oxygen concentration | Oxygen source pressure | Pressure | Ventilation per min Respiratory rate | Current leakage | Current volume | Trigger method | |
Other setting | Screen lock | Display brightness | Flow|Pressure | Waveform | Screen lock |Display brightness | Flow|Pressure | Waveform | Event summary |
Backup battery | 8 hours |
![]() |