Sign In | Join Free | My wneducation.com
wneducation.com
Products
Search by Category
Home > Titanium >

40mm Nitinol Self Expanding Covered Stent Esophageal

Categories Esophageal Stent
Brand Name: FN
Model Number: FN/401
Place of Origin: Jiangsu, China
Supply Ability: 50 Set/Sets per Day
Packaging Details: sterilized single-package single packed with white box(box size:680*260*30mm) 17 sets packed into a carton(carton size:685*280*515mm)
MOQ: 10 - 99 Sets
Price: $120.00
Certification: CE/ISO9001/ISO13485,TÜV CE0197 , GMP
Properties: Intervention Equipments
Type: Embolization Equipments
Licence Number: 2001-0381
Instrument classification: Class II
Raw material: Ni-Ti Alloy Super Elastic Wire
Name: esophageal stent
Usage: to dilate the esophagus
Length of stent: 40-120mm
Diameter of stent: 16mm-28mm
Length of introducer system: 700mm
Diameter of introducer system: 24Fr
covering material: silicon
Packaging Detail: single use Dialysis Bag
certificate: CE/ISO
Port: shanghai
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

40mm Nitinol Self Expanding Covered Stent Esophageal

self expanding nitinol medical cardia stent insertion

Esophageal stent

Esophageal stents are important tools for palliative treatment of inoperable esophageal malignancies. With the development of multiple self-expandable stents, there are now several therapeutic options for managing benign and malignant esophageal diseases. This paper discusses the various types of esophageal stents currently available, indications for their placement, challenges and complications that gastroenterologists face when placing these stents, and some of the innovations that will become available in the near future.


Specification table

(for esophageal stents ):

Stent diameter(mm)Length(mm)Specification of Introducer system
(Pipe diameter Fr × effective working length mm)
1660/80/100/120/14024Fr ×700
1860/80/100/120/14024Fr ×700
2060/80/100/120/14024Fr ×700
2260/80/100/120/14024Fr ×700

(for umbrella gastric fistula stents ):

Stent diameter(mm)MiddielendLength(mm)Specification of Introducer system
(mm)(Pipe diameter Fr × effective working length mm)
1818/26/4560/80/100/12024Frx 700
2020/26/4560/80/100/12024Frx 700

(for covered segmented esophageal stents ):

Stent diameter(mm)MiddielendLength(mm)Specification of Introducer system
(mm)(Pipe diameter Fr × effective working length mm)
1616/2460/80/100/120/14024Frx 700
1818/2660/80/100/120/14024Frx 700
2020/2860/80/100/120/14024Frx 700
2222/2860/80/100/120/14024Frx 700

The code of stent shape:



A.Straight ends K. Tulip end-ball end T. Single cup with anti-reflux

C. Single tulip end P. Tulip end-cup end G. Single cup end

D. Double tulip ends Q. Cup end-ball end H. Double cup ends

E. Single ball end R. Single tulip end with anti-reflux V. Straight end with anti-reflux

F. Double ball ends S. Single ball end with anti-reflux W. Segmented with double cup ends


Stent System Structure Sketch


As to the covering ways,please refer to the “covering instruction of esophagus stent

Covering instruction of esophagus stent

Conventional covering pattern

a. Uncovered

b. Ma (Partially covered)

c. Mb (Partially covered)

d. Mc (fully covered)


We also can offer follow customized covering pattern service:

e. Md (Partially covered)

f. Me (Partially covered)

g. Mf (Partially covered)

h. Mg (Partially covered)



Usage:

Be used to dilate the esophagus,cardia and anastomotic stoma stenosis and plug esophageal fistula.

Characteristics:

1. The stent will engender a continued gentle radial tensile force, acting on the inner wall of esophageal to expand the stenosis gradually and rebuilt the unobstructed passage.

2. The covered structure effectively avoids the tumor tissue ingrowth, reducing the possibility of second stenosis.

3. Lasso in the near-end of the stent, easy to be recycled.

4. Anti-refulx stents can be chosen to effectively restrain the gastroesophageal reflux disease.


Remark:

Gridding parts in the pictures means covered parts.


If you have anything puzzled ,pls feel free to let me know .


clean workshop


Work Site

Working process

Certificates

Shipping detail

Producing Lead time: 2-3 weeks after payment received, depends on your order quantity


Delivery Method:

1. By Express: Fedex, UPS, TNT, DHL, SF express 3-5day, 5-7days.

2. By Road: Domestic and neighbour country : 3-10 days

3. By Sea : 5-45 day all over the world.

4. By Air : 5-10 days all over the world.


Loading port :

Shenzhen, Yantian, Shekou, Hong Kong, Xiamen, Ningbo, Shanghai, Nanjing, Qingdao

According to your requirement.


Delivery Terms:


EXW, FOB, CIF, CFR, C&F, DDU, DDP, FCA, CPT


Shipping Documents:


B/L, Commercial Invoice, Packing List



Quality 40mm Nitinol Self Expanding Covered Stent Esophageal for sale
Send your message to this supplier
 
*From:
*To: Changzhou Chenmao Medical Devices Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0