Input power | 750W |
Recovery ability | 450g/min |
Charge ability | 1000g/min |
Vacuum ability | 5.4m3/h |
Cylinder capacity | 15kg |
Net weight | 70kg |
Dimension ( L*W*H,mm) | 1240*740*640 |
Safety caution
With Gloves and protective goggles to protect the skin and eyes
Do not use the machine near the fire or spark
Don’t sun and rain the machine
Avoid to touch corrosive liquids and gases
Keep good air circulation
Notes
1. Reading guide carefully before using the machine
2. Checking the refrigerant model before operation,only use R407a
3. In order to prevent the occurrence of serious accidents caused by
high pressure,recycle /refill the R407a not more than 8KG
4. Do not rotate,automatic radiator(eg:electric fan),heating
installation pipe nearly.
5. Check the height of the vacuum pump oil before use.
6. Recycling not more than 10 times an hour,otherwise it will cause
damage to the compressor.
7. Far from children when operating.
8. Only the professional technical person can operate.
9. With the manufacturer’s approval, do not disassemble.
10. Don’t turn the machine upside down.
11. If the refrigerant in the work bottle is less than 1kg, the
charging pressure will not work.