Heat Source Type: Air Source Heat Pump
Compressor: Panasonic DC Inverter Compressor
Motor: DC Inverter Brushless Motor
Function: heating, cooling, hot water
Power Supply: 220V-415V
telAmbient Air Temp: -30 to 43 Degree Celsius
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

DKFXRS-9I/CY Radiant Heat Pumps DC Inverter Air To Water Chiller

THE MOST ENERGY EFFICIENT AND INNOVATIVE SOLUTION OF GETTING DOMESTIC HEATING & COOLING & HOT WATER BY USING AIR SOURCE HEAT PUMP
Features of Radiant Heat Pumps Air To Water Chiller

The energy-saving control method of the floor radiant heating system of the variable-frequency heat pump water heater is characterized by the steps of the control method: the control system establishes the calculated temperature Tgj of the floor water supply and the ambient temperature of the room temperature according to the performance of the variable-frequency heat pump water heater and the heat load characteristics of the heating room. The functional formula between Tw; the control system establishes a functional formula between the room calculated air temperature Tnj and the ambient temperature Tw based on the thermal comfort of the human body; the control system adjusts the conversion according to the difference between the actual water supply temperature Tgs and the supply calculated temperature Tgj The compressor speed of the heat pump water heater makes the actual calculated water temperature Tgs and the calculated water temperature Tgj converge; the control system adjusts the opening of the three-way proportional control valve according to the difference between the actual room air temperature Tns and the room calculated air temperature Tnj, Make the room actual air temperature Tns and the room calculated air temperature Tnj converge. It has the advantages of higher energy efficiency of heat pump water heater, energy saving in operation and better thermal comfort of human body, etc.

CORE TECHNOLOGIES of Radiant Heat Pumps Air To Water Chiller
DC INVERTER COMPRESSOR Twin-Cylinder Rotary DC Inverter Compressor
INVERTER TECHNOLOGY: 40Hz-120Hz Wide Frequency operation range
SMART CONTROL SYSTEM:Hitachi DC Inverter Control System

The kinetic energy of subdivision, the water tank is free of washing for lifespan

Closed refrigerant system, safe and stable

Gold - aluminum condensation process rapid frost

Ship cabin positioning monitoring system, accurate detection of water temperature


Air source heat pumps series and application: Water heaters heat pump, swimming pool heat pumps, spa heaters, Radient/underfloor heating,cooling and hot water muldtifunction all in one heat pump

Application: swimming pool, household hot water, schools, restarants, Sauna, spas, day care center`````


We have various specifications and types of Radiant Heat Pumps Air To Water Chiller Air To Water Heat Pump For House Heating to offer, welcome to contact for furthder details

Triple supply parameters Cooling, heating and hot water functions
ItemKCHR-8I/BP
Side wind
KCHR-13I/BP
Side wind)
KCHR-15I/BP
Side wind
KCHR-15II/BP
(Out of the wind)
Rated voltage220V~50Hz220V~50Hz220V~50Hz380V 3N~50Hz
Cooling and heatingNominal cooling
capacity
7.8kW(2kW-9kW)13kW(3kW-15kW)14.5kW(4kW-16.5kW)14.5kW(4kW-16.5kW)
Nominal cooling power
consumption
2.77KW4.6KW5.27KW5.27KW
Nominal cooling(COP)2.812.822.752.75
IPLV4.114.134.024.02
Nominal heating capacity8.4kW(2.5kW-9.6kW)14kW(3.5kW-16kW)17kW(4.3kW-18.5kW)17kW(2.5kW-18.5kW)
Nominal heating power
consumption
2.78KW4.5KW5.6KW5.6KW
HeatingNominal heating capacity6.8KW10.5KW13KW13KW
Nominal heating
power consumption
1.75KW2.65KW3.3KW3.3KW
Nominal heating(COP)3.883.963.933.93
Maximum operating current20A33A41A21A
Maximum power consumption4KW6.6KW7.9KW7.9KW
Rated water flow1.34m²/h2.24m²/h2.5m²/h2.5m²/h
Refrigerant/charge volumeR410A/1750gR410A/4000gR410A/4000gR410A/4800g
noise≤54dB(A)≤56dB(A)≤57dB(A)≤58dB(A)
Water resistance≤14kPa≤15kPa≤21kPa≤21kPa
Maximum working pressure on low
pressure/high pressure side
4.5Mpa/0.15Mpa4.5Mpa/0.15Mpa4.5Mpa/0.15Mpa4.5Mpa/0.15Mpa
Allowable working pressure on
suction/exhaust side
4.5Mpa/0.15Mpa4.5Mpa/0.15Mpa4.5Mpa/0.15Mpa4.5Mpa/0.15Mpa
Anti-shock levelIIII
waterproof levelIPX4IPX4IPX4IPX4
Unit size (l× w × h)1030×410×865(mm)1030×410×1390(mm)1030×410×1390(mm)820×780×1700(mm)
(Cold and warm) Caliber of inlet
and outlet
DN25DN32DN32DN32
(Hot water) CaliberDN20DN25DN25DN25
Application area60㎡100㎡110㎡110㎡