Flow range: 0.15... 15m/s ; 0.02...+40ft/s
Measurement range: -12…+12m/s /-40...+40ft/s
Electrical conductivity:: ≥300μs/cm
Temperature:: +10~+30℃/+50~+80℉
Stroage temperature: -20~70℃
Ambient temperature: -20~+60℃
Power supply:: 110~240Vac
Signal Output: 4~20mA/Pulse
Electrode Material: SS316L
Explanation-Diameter: 1500mm
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement

    Electromagnetic Flow Meters Can Match with Computer for Fluid Measurement Range Rate 20:1


    GXEFM2000 Series Electromagnetic Flow Meter


    1.Description
    GXEFM2000 series electromagnetic flow meters are intended for fluid measurement in most industries including water, wastewater, food and beverage, pharmaceutical and chemical.
    There are two basic components of electromagnetic flow meter.
    The advantages of EFM2000 series electromagnetic flow meters are as follows.
    1:No obstacle existed in the measuring tube, so the pressure loss is zero, hardly blocked.
    2:The request of anticorrosion, wear resistance can be satisfied, if the proper electrodes and lining material are adopt.
    3:The measuring results have no relation with the physical parameters of liquid, such as pressure, temperature. Density viscosity, conductivity rate, etc. It is not influenced by the circumstances, so the accuracy is high, working process is stable and reliable.
    4: Adopt the dual row flow indicator of back lighted dot array, display the instantaneous and accumulative volume, simultaneously, also displays the working status, parameters, measuring units, etc.
    5: The measuring range is available of this flow meter is wide, lt's range rate normally is 20:1, generally can reach 150:1.
    6: This flow meter has multi-type outputs, can be matched with computer, combined instrument unit, can meet the requirements of printing, communication and networking.


    2.Technical Data

    Measuring system

    Measuring principle

    Faraday’s law


    Application rangeElectrically conductive fluids
    Measured Value
    Primary measured valueFlow velocity
    Secondary measured valueVolume flow
    Flow range

    0.15... 15m/s ;

    0.02...+40ft/s

    Flow medium attribution

    Electrical conductivity: ≥5μs/cm

    Medium temperature range -20 to 392˚F(-29 to 200˚C) Transient 480 ˚F(250 ˚C)

    Almost all kinds of acid alkali liquid


    Transmitter Selection

    260E is a split type electromagnetic Transmitter. 260D and 260A are compact type transmitter.

    TransmitterGeneral characteristics
    Infrared handing telecontrol keyboard,all the functions of far-untouched controlling converter.
    HART/Analog and Pulse outputs available, Modbus-RTU RS-485 and Pulse output available, Profibus-DP available
    Alarm OC outputs available, Empty pipe flow rate abnormal alarm available
    Recording time when power turn-off, to record power broken time of instrument system automatically and recruit to count the missing flux;Recording function of hour gross, to record the flux gross by hour, fit for timed measure;
    Multi language panel available.

    Infrared handing telecontrol keyboard,all the functions of far-untouched controlling converter.
    • 85V--250VAC and16V--36VDC;power supply available
    Multi language panel available
    Recording function of hour gross, to record the flux gross by hour, fit for timed measure;
    GPRS wireless communication available with battery power supply
    Multi language panel available.

    support multi sensors for 1 transmitter
    special for process control industry application
    Multi language panel available.

    Sensor type


    The pipe diameter of sensor is available from 15mm to 3000mm. choose the proper pipe diameter and size of the application field.

    Norminal Diamter (mm)

    Max Process Pressure MPa*LDD0Hhn-Ø
    104.015090602201024-Ø14
    1515095652221064-Ø14
    20150105752301104-Ø14
    25150115852351154-Ø14
    321501401002551224-Ø18
    401501501102601274-Ø18
    502001651252701404-Ø18
    652001851452751488-Ø18
    802002001602801548-Ø18
    1001.62502201802901638-Ø18
    1252502502103201758-Ø18
    1503002852403302008-Ø22
    2001.03503402953402208-Ø22
    25040039535036024012-Ø22
    30050044540040528512-Ø22
    3505005054604403016-Ø22
    40060056551547035016-Ø26
    45060061556550038020-Ø26
    50060067062053041020-Ø26
    60060078072559047020-Ø30
    70070089584065053024-Ø30
    800800101595072060024-Ø33
    9009001115105077065028-Ø33
    100010001405116083070028-Ø36
    12000.612001405134095080032-Ø33
    1400140016301560105090036-Ø36
    16001600183017601150100040-Ø36
    18001800204019701250110044-Ø39
    20002000226521801350120048-Ø42
    22000.252200240523401450130052-Ø33

    * higher pressure can be specially ordered, there are no product in storage.

    Liner Material Selection

    LinerNotesTemp limitsType and Line size

    NeopreneTypically applied to water and sea water. Abrasion resistant to slurries with small particles.

    0 to 185˚F

    (-18 to 85˚C)

    DN 50 - 2000

    2 - 80 inch

    PolyurethaneTypically applied to slurry (no chemicals). Abrasion resistant to slurries with small particles. special for slurry and chemical slurry

    0 to 140˚F

    (-18 to 60˚C)

    DN15 - 900

    0.5 - 36 inch

    FVMQTypically for high temperature waters, Abrasive resistance, but anti-corrosiveness performance not well

    0 to 392˚F

    (-18 to 200˚C)

    Transient 250 ˚C

    DN50-1200

    2-50inch

    F4(PTFE)

    BETTER FLUOROPOLYMER

    More cost effective than PFA. Excellent chemical resistance, but less abrasion resistance than PFA.

    -20 to 350˚F

    (-29 to 177˚C)

    DN10 -1600

    0.4 -63inch

    PFA

    BEST FLUOROPOLYMER

    Excellent resistance to chemicals and abrasion. Suitable for any application.

    -20 to 350˚F

    (-29 to 177˚C)

    DN10 – 400

    0.4-16 inch

    ETFE

    GOOD FLUOROPOLYMER

    Similar chemical and abrasion resistance to PTFE, but a lower maxium temperature and more expensive.

    -20 to 300˚F

    (-29 to 149˚C)

    Flanged 15–3000mm

    0.5 - 115 inch

    Wafer 15 - 200mm

    0.5 - 8inch


    Electrode Material Selection


    MaterialApplication Description
    316LSSTStandard electrode material. Compatible with most low concentration water based applications. Avoid using stainless in higher concentration acid applications. Such as municipal water supply, Industrial water supply, groundwater process, weak corrosive chemical fluid
    Hastelloy BIdeal for hydrochloric acid(concentration lower than10% v/v),phosphate, organic acids, sodium hydroxide.
    Hastelloy C276Use in medium to high concentration acids where SST is not acceptable. Use in applications with high chloride concentrations, such as sea water,
    PlatinumIdeal for liquor applications found in pulp and paper industry. Also ideal as a spare electrode option to cover nearly every application in a plant. Compatible with nearly every process fluid.
    TantalumIdeal for high concentration acid flows such as hydrochloric and hydrofluoric acids.
    TitaniumIdeal for high concentration caustic (base) applications such as sodium and potassium hydroxides.
    wolfram carbide

    Ideal for paper pulp, sewage some kind of slurry with micro particles;

    Not proper for Inorganic acid, Organic acids, oxide fulid.


    Ask for suggestion before ordering about the Electrode Material needed


    3.Ordering information


    Model Suffix Code Description
    GXEFM2000-1200-Com-4mA-Hart-DC-Pt-Teflon1-GR-D1400-Exd IIC T6 Gb 
    Diameter-XXXX         Four Digitals: for example:0010: 10mm: 0015:15mm 0100: 100mm 1000: 1000mm
    Transmitter-Com        Compact type
    -Rem        Remote type
    -Bat        Battery power supply type
    -PRO        process control type
    Signal Outpt-N       No output
    -4mA       4-20mA
    -Pul       1~5KHz pulse
    -4Pul       4~20mA / 1~5KHz
    Communication-N      No communication
    -Hart      HART
    -MOD      MODBUS-RTU
    -PRO      PROFIBUS
    -GPRS      GPRS net
    -CDMA      CDMA net
    -WHRT      Wireless HART
    -Other      special order
    Power Supply-AC     85V~250Vac@46~63Hz
    nominal 20W
    -DC     20~36VDC nominal 20W
    -Bat     Battery power supply
    -Bat+     Battery +12Vdc dual power supply
    Other     special request
    Electorde Material-316L    Stainless steel 316L
    -HasB    Hastelloy B
    -HasC    Hastelloy C276
    -Pt    Platinum
    -Ta    Tantalum
    -Ti    Titanium
    -WC    wolfram carbide
    Liner material-Rub1   Neoprene(-20-60℃)
    -Rub2   Neoprene(-20-90℃)
    -Tef1   polytetrafluroethylene(-30-120℃)
    -Tef2   polytetrafluroethylene(-20-160℃)
    -P   Polyurethane
    -FVMQ   FVMQ
    -PFA   DFA
    -ETFE   Ethylene tetraflurorethylene
    Grounding Ring-N  No grounding ring
    -GR  Grounding ring
    -GE  Grounding Electrode
    Wet part Connection attribute-DXX DXX: D06, D10, D16, D25,D40 D06: DIN PN6:
    D10: DIN PIN10D16: DIN PN16; D25: DIN PN25 D40: DIN PN40 etc
    -AX AX: A1, A3, A6 A1: ANSI 150#; A3: ANSI 300# A6: ANSI 600#
    -JX JX: J1, J2, J3 J1: JIS10K;
    J2: JIS 20K; J3: JIS 30K
    -WF Wafer connection (available for DN2.5; DN6 flow meter) Body material: stainless steel
    -TR Tri-Clamp for sanitary type (Body material: stainless steel)
    Explosive-proof grade-Exd IIC T6 GbExd IIC T6 Gb
    -Ndon't need

    Quality GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement for sale
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 wneducation.com. All rights reserved.