Sign In | Join Free | My wneducation.com
wneducation.com
Products
Search by Category
Home > Measuring & Analysing Instrument Design Services >

Professional Stability High Low Temperature And Humidity Test Chamber

Categories Temperature Humidity Chamber
Brand Name: Haida
Model Number: HD-E702
Certification: CE,,ISO
Place of Origin: China
MOQ: 1
Price: Negotiation
Payment Terms: L/C, T/T, D/A, D/P, Western Union, MoneyGram
Supply Ability: 75 Piece / Pieces Per Month
Delivery Time: 15 Days After Order
Packaging Details: Strong Wooden Case
Usage: Constant Temperature and Humidity Testing Machine
Temp. range: -70°C~150°C
Humid. range: 10~ 98 percent R.H.
Resolution: 0.01°C, 0.1 percent, P.I.D control
Heating up: -40°C ~ +100°C within 45 min
Interior material: Stainless steel plate(SUS304)
Insulation: Rigid foam
Power: AC220V±10 percent 50/60Hz
Use: temperature humidity testing chamber
Company Info.
Hai Da Labtester
Verified Supplier
View Contact Details
Product List
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Professional Stability High Low Temperature And Humidity Test Chamber

    Professional Stability High Low Temperature And Humidity Test Chamber


    Temperature and humidity chamber.pdf


    1. Performance of Stability High Low Temperature and Humidity Test Machine:


    Get a performance evaluation to help provide the suitable chambers to you.


    For better assurance of performance for your temperature and humidity cycling application, Haida can provide a guaranteed performance calculation based on your submitted requirements.


    Please use these questions as below as a guide to define your test plan. You can then give this information to our lab consultant or email to us, for review by our lab consultant. A recommended model with appropriate refrigeration size will provide to you.


    Questions for Performance Evolution Request:


    temperature humidity testing chamber


    System & Performance Options

    • Low and Ultra-Low Humidity Extends the humidity control range. (Normal Humidity Range Diagramed)
    • Water-cooling system.
    • Dry Air Purge keeps moisture in the chamber extremely low by purging with -40 °C. Compressed air supply required
    • Additional shelves, 50 Kg loading
    • Cable ports with flexible silicone plug, 50 , 100, 150mm or customer specific diameters

    Professional Stability High Low Temperature And Humidity Test Chamber is suitable materials, electrical and electronic products, household appliances, auto parts, chemical coatings, humidity chamber at the same time for a variety of electronic components and other related product components stored at high temperature, low temperature environment, transport, use of adaptation test, assess its performance.


    Uses:

    Electrical, instrumentation, chemical, biological / pharmaceutical products such as high temperature, performance testing, Humidity Chamber low temperature environment is the product development process for high-temperature environment testing or


    2. Specifications of Stability High Low Temperature and Humidity Test Machine:


    Range – 70 to 150°C

    Temp/Humidity

    HD-E702-100-7

    HD-E702-150-7

    HD-E702-225-7


    HD-E702-408-7

    HD-E702-800-7

    HD-E702-1000-7

    Temp-only

    HD-E702-100T-7

    HD-E702-150T-7

    HD-E702-225T-7


    HD-E702-408T-7

    HD-E702-800T-7

    HD-E702-1000T-7

    Temperature Range:

    -70°C ~150°C

    Cooling Capacity

    ~ 2.5 kW at -50°C

    ~ 3 kW at -50°C

    ~ 5 kW at -50°C

    ~ 6.5 kW at-50°C

    ~ 8.5 kW at -50°C

    ~ 9 kW at - -50°C

    Heating System

    ~ 5 kW

    ~ 5 kW

    ~ 5.5 kW

    ~6.5 kW

    ~ 8.5 kW

    ~ 9 kW

    Temperature Fluctuation:

    ±0.5°C

    Temperature Gradient:

    ±0.5°C~±0.2°C

    Heating Rate†:

    ≥3℃ / min average ( Advance model 5 – 15 ℃ / min)

    Cooling Rate†:

    ≥1℃ / min average (Advance model 5 - 15℃ / min)

    Humidity Range:

    10%~95%RH (Ref to Normal Humidity Range Diagramed)

    Humidity Fluctuation:

    ±1.5%RH~±2.0%RH

    Humidity Gradient:

    ±3%RH

    Dimensions

    Workspace dimensions
    (WxDxH)mm:

    500x400x500

    HD-E702-100

    600x500x500

    HD-E702-150

    750x500x600

    HD-E702-225


    850x650x800

    HD-E702-800

    1000x1000x800

    HD-E702-800

    1000x1000x1000

    HD-E702-1000

    Exterior dimensions
    (WxDxH)mm:

    1400x850x1050

    1500x950x1050

    1650x950x1150


    1750x1050x1350

    1900x1450x1350

    1900x1450x1550

    Site Requirements

    Electrical Supply:

    208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific)

    Humidity Water

    Distilled water

    Condensate Drain:

    1/2" hose connection (gravity drain)


    Range – 40 to 150°C


    Temp/Humidity

    HD-E702-100-4

    HD-E702-150-4

    HD-E702-225-4


    HD-E702-408-4

    HD-E702-800-4

    HD-E702-1000-4

    Temp-only

    HD-E702-100T-4

    HD-E702-150T-4

    HD-E702-225T-4


    HD-E702-408T-4

    HD-E702-800T-4

    HD-E702-1000T-4

    Temperature Range:

    -40°C ~150°C

    Cooling Capacity

    ~ 2 kW at -20°C

    ~ 2.5 kW at -20°C

    ~ 4.5 kW at -20°C

    ~ 5.5 kW at-20°C

    ~ 8 kW at -20°C

    ~ 8.5 kW at - -20°C

    Heating System

    ~ 5 kW

    ~ 5 kW

    ~ 5.5 kW

    ~6.5 kW

    ~ 8.5 kW

    ~ 9 kW

    Temperature Fluctuation:

    ±0.5°C

    Temperature Gradient:

    ±0.5°C~±0.2°C

    Heating Rate†:

    ≥3℃ / min average ( Advance model 5 – 15 ℃ / min)

    Cooling Rate†:

    ≥1℃ / min average (Advance model 5 - 15℃ / min)

    Humidity Range:

    10%~95%RH (Ref to Normal Humidity Range Diagramed)

    Humidity Fluctuation:

    ±1.5%RH~±2.0%RH

    Humidity Gradient:

    ±3%RH

    Dimensions

    Workspace dimensions
    (WxDxH)mm:

    500x400x500

    HD-E702-100

    600x500x500

    HD-E702-150

    750x500x600

    HD-E702-225


    850x650x800

    HD-E702-800

    1000x1000x800

    HD-E702-800

    1000x1000x1000

    HD-E702-1000

    Exterior dimensions
    (WxDxH)mm:

    1400x850x1050

    1500x950x1050

    1650x950x1150


    1750x1050x1350

    1900x1450x1350

    1900x1450x1550

    Site Requirements

    Electrical Supply:

    208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific)

    Humidity Water

    Distilled Water

    Condensate Drain:

    1/2" hose connection (gravity drain)


    Control System


    Imported microcomputer temperature controller wet integrated controller (display directly percent humidity).
    Accuracy range setting accuracy: temperature ± 0.1 ℃, humidity ± 0.1% R · H, indicating accuracy: temperature ± 0.1 ℃, temperature ± 0.1% R · H temperature and humidity sensors platinum platinum resistance · PT100Ω.
    Heating system is completely independent system, electric heating nichrome heater.
    Isolated external humidification systems, stainless steel boiler type shallow surface evaporative humidifier.
    Circulatory system temperature low noise air conditioning motors, leafy centrifugal wind wheel.


    Heating system


    Far-infrared heating using nickel-chromium alloy heating wire heating speed;
    High temperature, low temperature completely independent systems;
    Temperature control P · I · D + S · S · R system with channel coordination control;
    Temperature control the output power by the microcomputer calculus, to achieve high accuracy and high efficiency power efficiency.



    Cooling System


    Refrigeration cycle are used against the card if the cycle, which consists of two isothermal and two adiabatic processes, whose process is as follows: a refrigerant through the compressor adiabatic compression to a higher pressure, the power consumption of the exhaust gas temperature, after the temperature of the refrigerant through the condenser and other places in and around medium heat exchange medium heat to four weeks. After the refrigerant flows through the shutoff valve adiabatic expansion work, when the refrigerant temperature decreases. Finally, the refrigerant passes through the evaporator isothermal heat from high temperature object, the object to be cooled so that the temperature is lowered. This loop again and again to achieve the purpose of cooling.


    Standard Features:

    • Stainless# 304 steel for interior
    • Paint steel for exterior
    • Foam-insulated door for rigidity and long life
    • Plastic water tank easy for maintenance
    • Observation Window with frost free function
    • High performance refrigeration system
    • Easy user interface for TEMI-880 PLC controller
    • One 100mm cable port/ Customer specified
    • One shelve, 10 Kg loading & 4 casters included
    • Van Type Sirocco,L134,Fan
    • PID controlled-Stainless Steel Humidifier
    • DuPont R-404A [No Fluorine] Refrigerant / 23 for below -40 °C
    • USB port for data output
    • Anti-explosive interior lamps
    • Data logging chart recorders, paperless recorders stored data in the PLC.

    Energy-saving Design:


    In addition to fully consider the safety of refrigeration units, efficient use of all sectors, but while taking multiple energy saving measures: such as: adjusting the cooling capacity of the refrigeration system, liquid-gas bypass regulation, evaporation temperature regulation, low temperature at any point when the thermostat without heat balance, operating power can be reduced to half, so that operating costs and failure rates of the refrigeration system down to a more state of the economy.
    Intelligent automatic transfer system expansion, the load automatically adjust the refrigerant flow + intelligent electric power data value (%) to match heating and cooling (load) Analog output data automatically according to the output value. This design than the traditional design saving more than 30%.


    4. Professional Stability High Low Temperature and Humidity Test Machine view:


    temperature humidity testing chamber

    Maintain:


    1. cabinets outside temperature and humidity chamber cleaning and maintenance
    (1) temperature and humidity chamber at operation should be preceded by internal impurities removed.
    (2) distribution room be cleaned at least once a year
    Or more, can take advantage of a vacuum cleaner to clean indoor dust can be removed by suction.
    (3) the outer casing shall be cleaned once a year or more, first with soap and water to wipe cleaning.
    2. Check the temperature and humidity of the storage chamber humidifier humidifier maintenance within and should be replaced once a month to ensure clean water, humidification water dish should be cleaned every month to ensure smooth flow of water.

    Quality Professional Stability High Low Temperature And Humidity Test Chamber for sale
    Send your message to this supplier
     
    *From:
    *To: Hai Da Labtester
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们